卷簾門(mén)消防驗收過(guò)程中可能遇到的問(wèn)題
來(lái)源:http://www.kalkulackapro.top 日期:2023-01-28 發(fā)布人:
1.窗簾板的涂層脫落并生銹。簾板有明顯的壓坑、凹凸和透孔。濟南卷簾門(mén)是一個(gè)完整的消防產(chǎn)品。如果簾板有問(wèn)題,將直接影響卷簾式卷簾門(mén)的耐火極限指標。
1. The coating of curtain board falls off and rusts. The curtain plate has obvious indentation, concave-convex and through-hole. Jinan rolling shutter door is a complete fire protection product. If there is a problem with the shutter, it will directly affect the fire endurance index of the roller shutter door.
2.導軌變形或落地窗簾卡不平穩。卷簾門(mén)通常沿著(zhù)導軌移動(dòng)。如果導軌扭曲或斷裂,卷簾門(mén)無(wú)法移動(dòng)到指定位置,無(wú)法達到分隔的效果。
2. The guide rail is deformed or the floor curtain card is unstable. The roller shutter usually moves along the guide rail. If the guide rail is twisted or broken, the roller shutter door cannot move to the specified position and cannot achieve the separation effect.
3.卷簾的上下限位置失效或限位線(xiàn)連接錯誤。這種情況經(jīng)常發(fā)生在中庭的卷簾上。由于中庭的卷簾有時(shí)安裝在上層走道的外面,導致卷簾下的樓層無(wú)法關(guān)閉,大的縫隙漏出來(lái),無(wú)法實(shí)現上下樓層的分隔。
3. The upper and lower limit positions of the roller shutter are invalid or the limit line is connected incorrectly. This often happens on the rolling curtain of the atrium. Because the roll-up curtain of the atrium is sometimes installed outside the upper walkway, the floors under the roll-up curtain cannot be closed, large gaps leak out, and the separation between the upper and lower floors cannot be achieved.
4、操作不動(dòng)作,按鈕觸點(diǎn)燒壞,線(xiàn)路受阻或簾板只上下、相位不對、上下顛倒。一些卷簾門(mén)安裝在普通走道或疏散走道上,通過(guò)這些走道需要疏散人員,這將不可避免地需要一個(gè)裝置來(lái)手動(dòng)控制卷簾門(mén)的移動(dòng)。如果設備損壞,將會(huì )帶來(lái)不必要的傷亡和損失。
4. The operation does not work, the button contact is burnt, the line is blocked, or the curtain is only up and down, the phase is wrong, and the up and down are reversed. Some roller shutter doors are installed on common walkways or evacuation walkways, through which people need to evacuate, which will inevitably require a device to manually control the movement of roller shutter doors. If the equipment is damaged, it will cause unnecessary casualties and losses.
卷簾門(mén)消防驗收過(guò)程中可能遇到的問(wèn)題現在就講解了四個(gè)方面,您有怎樣的需求就來(lái)我們網(wǎng)站http://www.kalkulackapro.top咨詢(xún)吧!
The problems that may be encountered in the fire inspection and acceptance process of rolling shutter doors are explained in four aspects now. If you have any requirements, please come to our website http://www.kalkulackapro.top Ask!
閱讀/ Recommended reading
- 濟南卷簾門(mén)的故障維修與更換卷簾門(mén)注意事項 2024-07-19
- 選錯濟南卷簾門(mén)的后果居然有這么嚴重? 2024-07-13
- 電動(dòng)卷簾門(mén)保養知識介紹 2024-06-14
- 彩鋼板卷簾門(mén)基本介紹 2024-06-04
- 電動(dòng)卷簾門(mén)遙控器配對方法 2024-06-17
- 濟南卷簾門(mén)由哪幾部分組成? 2024-05-24
- 濟南卷簾門(mén):卷簾門(mén)鑰匙怎么配對? 2024-05-21
- 濟南卷簾門(mén):卷簾門(mén)常見(jiàn)故障 2024-05-16
濟南卷簾門(mén):卷簾門(mén)(不銹鋼款)
2024-07-25
不銹鋼卷簾門(mén)是一種采用不銹鋼材料制成的卷簾門(mén)。不銹鋼具有良好的耐腐蝕性、抗氧化性和高強度等特點(diǎn),因此不銹鋼卷簾門(mén)在防盜、防火、隔音等方面具有較好的性能?! tainless ...